Page 18
490X Engineer’s Reference Guide
Programming Zones
1) With the display showing:-
2) Enter the Engineer code (1234 default)
The display will show:-
3) Enter the Authorisor code. The Authorisor code is
the Master User, (default 5678).
The display will show:-
4) Press YES. The display will show:-
This is Engineer Mode
5) Press Yes. The display will show:-
6) Press Yes. The display will show:-
7) Enter the zone number you wish to program
e.g 1 followed by Yes. The display will show,
for example:-
8) Press No. The display will show:-
9) Note the chevron has now appeared before
the Zone Type. Now press the No key until the
Zone Type you require is displayed.
01 Jan 00: 00: 01
Program . . . . _ _ _
Zones ?
Program Zone
Types ?
Enter Zone # _ _ _
001 = Ent/Ex
= Remove -
001 > Ent/Ex
= Remove -
Enter Authorisor
Code . . . . . .
Do you want to . .
Use ENGNR. Mode ?
490X 1.qxd 11/07/2006 12:32 Page 18