Page 38
490X Engineer’s Reference Guide
Programming Entry Times
Two Entry Times are available (Entry Time 1 & Entry Time 2). On entry to the premises
via the Entry Door Entry Time 1 will start. If deviation from Entry Route during Entry
Time 1 then Entry Time 2 starts. Entry Time 2 is 30 seconds and cannot be changed.
Note that comms cannot take place until the later of the theoretical expiry of Entry
Time 1, or the expiry of Entry Time 2.
Note: Entry Time 1 is defaulted to 30 seconds but maybe changed to a maximum
of 45 seconds.
Note: Entry Time 2 is defaulted to 30 seconds and may not be changed.
1) Enter into Engineer Mode
To do this follow Steps 1 to 4 on page 18
With the display showing:-
2) Press No twice. The display will show:-
3) Press Yes. The display will show:-
4) Press Yes. The display will show:-
5) Press No twice. The display will show:-
6) Enter the Time required (in seconds) followed by
Yes. The display will show:-
Program . . . . _ _ _
Zones ?
Program . . . . _ _ _
Entry Times ?
Program Entry
Time 1 ?
Program Entry
Time 1 ?
Entry Time 1 = 30s
Entry Time 1 > _ _s