Page 93
490X Engineer’s Reference Guide
14) Press 0 (zero) three times. The display will show:-
Linefault Sounders Description
The Linefault Sounder option determines how the system sounders (speakers) will
react when a Linefault is detected. Below are the options available and a description of
each option.
On if Set Linefault Sounders will operate when the system is Set and a
Linefault is detected (may be silenced by User Code).
On if Unset Linefault Sounders will operate when the system is Unset and a
Linefault is detected. (may be silenced by User Code)
FLT if Off A fault tone will be generated when the system is Unset and a
Linefault is detected (may not be silenced by User Code).
Beep if Off A periodic beep will be generated when the system is Unset and a
Linefault is detected (may not be silenced by User Code).
Always On Linefault Sounders are always On (Set or Unset) (may not be
silenced by User Code).
01 Jan 00: 00: 01
490X 1.qxd 11/07/2006 12:32 Page 93