Reporting a Mains Fail on a PSU.
In order to report a Mains Fail on a PSU the Fault output on
the PSU would be wired to a Zone on the Control Panel.
The Zone Type would be programmed as ‘Fault’.
Program the Zone Descriptor as External PSU.
At the end of the Program Zones menu we have a menu called Program Events Tags,
enter this option and select the Zone number you have programmed as Fault.
Program the Tag as Mains Fail. Then program a Digi Channel as Mains Fail.
This will allow for full reporting of External PSUs.
Page 30
490X Engineer’s Reference Guide
Program Zone
Event Tags ?
490X 1.qxd 11/07/2006 12:32 Page 30