Page 59
490X Engineer’s Reference Guide
9) Press No. The display will show:-
10) Press Yes. The display will show:-
Note: Line Fault is defaulted to Limited and may not be changed.
This limit is set to 3 events.
11) Press Yes. The display will show:-
12) Press No. The display will show:-
13) Press Yes. The display will show:-
With Detect programmed as 00 Linefault detection is instant or it may be delayed
if required.
14) Press No twice. The display will show:-
15) Enter the time you require (in seconds) followed
by Yes. The display will show:-
16) This concludes the programming for
Linefault Sounders. Press 0 (zero) to return to:-
Or
Press 0 (zero) until the display shows:-
For information on Linefault Sounders refer to page 93
Program Lineflt
Log Mode ?
Program Lineflt
Log Mode ?
Program Lineflt
Detect Time ?
Program Lineflt
Detect Time ?
Detect
= 30 Secs
Detect
> _ _ Secs
Lineflt Log
: Limited
Program . . . . _ _ _
Linefault Modes ?
01 Jan 00: 00: 01