Page 83
490X Engineer’s Reference Guide
a) Scenario specific to systems using completion of unsetting with ACE
6.4.5 DD243.
Event 1 System Set
Event 2 Entry Time Starts
Event 3 Access Zone Triggered
Event 4 Entry Expired (including Entry Time 2) Unconfirmed
Transmitted
Event 5 non entry/access Zone Triggered
Event 6 Second non entry.access Zone Triggered Confirmed
Transmitted
To achieve the above
Confirm on entry = On
Ace Low Battery = On
b) Scenario Unlocking the initial entry door disables all means of
conformation 6.4.3 DD243.
Event 1 System Set
Event 2 Entry Door Unlocked Confirmed Alarms Disabled
Event 3 Open Entry Door (entry time starts)
Event 4 Entry Time Expires (inc Entry Time 2) Unconfirmed Alarm
Transmitted
Event 5 Any subsequent zones triggered No Confirmed Signals
Transmitted
Or
Event 1 System Set
Event 2 Entry Door Forced Open (entry time starts)
Event 3 Entry Time Expires (inc Entry Time 2) Unconfirmed Alarm
Transmitted
Event 4 non entry/access Zone Triggered
Event 5 Second non entry.access Zone Triggered Confirmed
Transmitted
To achieve the above
Confirm on entry = On
ET Mode = Door Lock
Door Lock Zone programmed as ET
490X 1.qxd 11/07/2006 12:32 Page 83