PART #4526396 (03/30/10)
GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION SERVICE MANUAL
Page 11
SPECIFICATIONS
SUPPLY
REQUIRED
TOTAL
kW
LOAD
LOADING: (kW/
PHASE)
NOMINAL AMPS PER LINE
208V / 220V / 240V 208V / 60Hz 220V / 60Hz 240V / 60Hz
L1/L2 L1/L3 L2/L3 L1 L2 L3 L1 L2 L3 L1 L2 L3
INPUT 1 10.0 3.25 3.25 3.25 28.0 28.0 28.0 26.3 26.3 26.3 24.0 24.0 24.0
GAS INPUT
GAS
MAX INPUT
NET PER
BURNER
BTU/H
TOTAL INPUT
RATING
BTU/H
INJECTOR
SIZE
AIR SHUTTER
SETTING
MM
SUPPLY
PRESSURE
IN W.C.
BURNER
MANIFOLD
PRESSURE
IN W.C.
NATURAL GAS 32,000 96,000 #35 4.8 3.5 3.5
PROPANE 32,000 96,000 #43 4.8 3.5 3.5
3N~ 400V
50Hz
TOTAL kW
LOAD
LOADING: (kW/PHASE) NOMINAL AMPS PER LINE
MENNEKES
PLUG &
RECEPTACLE
MAY BE
REQUIRED
L1/L2 L1/L3 L2/L3 L1 L2 L3
10.0 3.25 3.25 3.25 14.1 14.1 14.1 Type 748
GAS INPUT
GAS GROUP
MAX INPUT
NET PER
BURNER kW
TOTAL
INPUT
RATING
kW
INJECTOR
SIZE
AIR
SHUTTER
SETTING
mm
SUPPLY
PRESSURE
mbar
BURNER
PRESSURE
mbar
VOLUMETRIC
GAS RATE
G20 NG 8.9 26.7 2.79mm (#35) 4.8 20/25 8.7 0.940 m
3
/h
G25 NG 2.79mm (#35) 4.8 20 8.7
G31 LPG 8.9 26.7 2.26mm (#43) 4.8 37/50 8.7 0.69 kg/h
NET HEATING VALUE BY GAS GROUP
G20 G25 G31
34.02 MJ/m
3
; 0.555 SG 29.25 MJ/m
3
; 0.613 SG 88.0 MJ/m
3
(46.34 MJ/kg); 1.55 SG
GAS CATEGORIES
CATEGORY DESTINATION COUNTRIES SUPPLY PRESSURE (mbar)
I
2H
AT, CH, CZ, DK, ES, FI, GB, IE, IS, IT, NO, PT, SE 20.0
I
2E
DE, LU 20.0
I
2L
NL 25.0
I
2ER
FR 20.0 / 25.0
I
3P
NL 30.0
I
3P
BE, CH, CZ, ES, FR, GB, GR, IE, LU 37.0
I
3P
BE, CH, DE, CZ, ES, FR, NL 50.0
Input Specications, GAS Grills, North America:
Input Specications, GAS Grills, CE Approved Model MWG3W-CE: