13-248 8 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
CHAPTER 13: MODBUS MEMORY MAP
72402 0x7E91 Pickup 50 30000 1 x CT F3 300 1 Y Y
72403 0x7E92 Slope 0 100 1 % F0 50 1 Y Y
72404 0x7E93 Pickup Delay 0 6000000 1 s F13 100 2 Y Y
72406 0x7E95 Gnd Curr Superv 0 1 1 FC126 0 1 Y Y
72407 0x7E96 Gnd Curr Superv Level 50 30000 1 x CT F3 300 1 Y Y
72408 0x7E97 Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y
72410 0x7E99 Block 0 0xC6CD00 1 FC142 0 2 Y Y
72412 0x7E9B Events 0 1 1 FC126 1 1 Y Y
72413 0x7E9C Targets 0 2 1 FC101 1 1 Y Y
Restricted Ground Fault 3
72427 0x7EAA Function 0 4 1 FC100 0 1 Y Y
72428 0x7EAB Signal Input 1 5 1 FC102A 1 1 Y Y
72429 0x7EAC Pickup 50 30000 1 x CT F3 300 1 Y Y
72430 0x7EAD Slope 0 100 1 % F0 50 1 Y Y
72431 0x7EAE Pickup Delay 0 6000000 1 s F13 100 2 Y Y
72433 0x7EB0 Gnd Curr Superv 0 1 1 FC126 0 1 Y Y
72434 0x7EB1 Gnd Curr Superv Level 50 30000 1 x CT F3 300 1 Y Y
72435 0x7EB2 Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y
72437 0x7EB4 Block 0 0xC6CD00 1 FC142 0 2 Y Y
72439 0x7EB6 Events 0 1 1 FC126 1 1 Y Y
72440 0x7EB7 Targets 0 2 1 FC101 1 1 Y Y
Switch On To Fault 1
72540 0x7F1B Function 0 4 1 FC100 0 1 Y
72541 0x7F1C VT Input 0x12 0x28 1 FC103C 0x12 1 Y
72542 0x7F1D CT Input 1 5 1 FC102A 1 1 Y
72543 0x7F1E Dead Line Max Voltage 5 100 1 x VT F2 20 1 Y
72544 0x7F1F Dead Line Max Current 5 100 1 x CT F2 5 1 Y
72545 0x7F20 Dead Line Pickup Delay 0 6000000 1 s F13 10000 2 Y
72547 0x7F22 SOTF Max Voltage 5 300 1 x VT F2 50 1 Y
72548 0x7F23 SOTF Current Pickup 5 1000 1 x CT F2 200 1 Y
72549 0x7F24 SOTF Detection Window 0 6000000 1 s F13 500 2 Y
72551 0x7F26 External SOTF Trigger 0 0xC6CD00 1 FC142 0x0000 2 Y
72553 0x7F28 Pickup Delay 0 6000000 1 s F13 0 2 Y
72555 0x7F2A Block 0 0xC6CD00 1 FC142 0x0000 2 Y
72557 0x7F2C Relays 0 0xFFFFFFFF 1 FC198 0 2 Y
72559 0x7F2E Events 0 1 1 FC126 1 1 Y
72560 0x7F2F Targets 0 2 1 FC101 2 1 Y
Switch On To Fault 2
72561 0x7F30 Function 0 4 1 FC100 0 1 Y
72562 0x7F31 VT Input 0x12 0x28 1 FC103C 0x12 1 Y
72563 0x7F32 CT Input 1 5 1 FC102A 1 1 Y
72564 0x7F33 Dead Line Max Voltage 5 100 1 x VT F2 20 1 Y
72565 0x7F34 Dead Line Max Current 5 100 1 x CT F2 5 1 Y
72566 0x7F35 Dead Line Pickup Delay 0 6000000 1 s F13 10000 2 Y
72568 0x7F37 SOTF Max Voltage 5 300 1 x VT F2 50 1 Y
Modbus
Address
Hex
Address
Description Min Max Step Units Format
Code
Factory
Default
Size in
Words
8
5
0
8
6
9
8
8
9
8
4
5

Table of Contents