13-306 8 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
CHAPTER 13: MODBUS MEMORY MAP
84369 0xAD50 Compare -2147483648 2147483647 1 F30 0 2 Y Y Y Y
84371 0xAD52 Up 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84373 0xAD54 Down 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84375 0xAD56 Set to Pre-set 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84377 0xAD58 Reset 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84379 0xAD5A Freeze/Reset 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84381 0xAD5C Freeze/Count 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84383 0xAD5E Block 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84385 0xAD60 HI 6 Output Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y Y Y
84387 0xAD62 EQL 6 Output Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y Y Y
84389 0xAD64 LO 6 Output Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y Y Y
84391 0xAD66 Events 0 1 1 FC126 1 1 Y Y Y Y
Digital Counter 7
84392 0xAD67 Function 0 1 1 FC126 0 1 Y Y Y Y
84393 0xAD68 Name 0 65535 1 F60_26 Counter 7 13 Y Y Y Y
84406 0xAD75 Units 0 65535 1 F60_6 units 3 Y Y Y Y
84409 0xAD78 Pre-set -2147483648 2147483647 1 F30 0 2 Y Y Y Y
84411 0xAD7A Compare -2147483648 2147483647 1 F30 0 2 Y Y Y Y
84413 0xAD7C Up 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84415 0xAD7E Down 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84417 0xAD80 Set to Pre-set 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84419 0xAD82 Reset 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84421 0xAD84 Freeze/Reset 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84423 0xAD86 Freeze/Count 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84425 0xAD88 Block 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84427 0xAD8A HI 7 Output Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y Y Y
84429 0xAD8C EQL 7 Output Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y Y Y
84431 0xAD8E LO 7 Output Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y Y Y
84433 0xAD90 Events 0 1 1 FC126 1 1 Y Y Y Y
Digital Counter 8
84434 0xAD91 Function 0 1 1 FC126 0 1 Y Y Y Y
84435 0xAD92 Name 0 65535 1 F60_26 Counter 8 13 Y Y Y Y
84448 0xAD9F Units 0 65535 1 F60_6 units 3 Y Y Y Y
84451 0xADA2 Pre-set -2147483648 2147483647 1 F30 0 2 Y Y Y Y
84453 0xADA4 Compare -2147483648 2147483647 1 F30 0 2 Y Y Y Y
84455 0xADA6 Up 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84457 0xADA8 Down 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84459 0xADAA Set to Pre-set 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84461 0xADAC Reset 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84463 0xADAE Freeze/Reset 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84465 0xADB0 Freeze/Count 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84467 0xADB2 Block 0 0xC6CD00 1 FC142 0 2 Y Y Y Y
84469 0xADB4 HI 8 Output Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y Y Y
84471 0xADB6 EQL 8 Output Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y Y Y
84473 0xADB8 LO 8 Output Relays 0 0xFFFFFFFF 1 FC198 0 2 Y Y Y Y