A-12 F35 Multiple Feeder Protection System GE Multilin
A.1 PARAMETER LIST APPENDIX A
A
9137 Fault Location [2] --- Fault 3 location
9138 Prefault Ia Mag [3] Amps Fault 4 pre-fault phase A current magnitude
9140 Prefault Ia Ang [3] Degrees Fault 4 pre-fault phase A current angle
9141 Prefault Ib Mag [3] Amps Fault 4 pre-fault phase B current magnitude
9143 Prefault Ib Ang [3] Degrees Fault 4 pre-fault phase B current angle
9144 Prefault Ic Mag [3] Amps Fault 4 pre-fault phase C current magnitude
9146 Prefault Ic Ang [3] Degrees Fault 4 pre-fault phase C current angle
9147 Prefault Va Mag [3] Volts Fault 4 pre-fault phase A voltage magnitude
9149 Prefault Va Ang [3] Degrees Fault 4 pre-fault phase A voltage angle
9150 Prefault Vb Mag [3] Volts Fault 4 pre-fault phase B voltage magnitude
9152 Prefault Vb Ang [3] Degrees Fault 4 pre-fault phase B voltage angle
9153 Prefault Vc Mag [3] Volts Fault 4 pre-fault phase C voltage magnitude
9155 Prefault Vc Ang [3] Degrees Fault 4 pre-fault phase C voltage angle
9156 Postfault Ia Mag [3] Amps Fault 4 post-fault phase A current magnitude
9158 Postfault Ia Ang [3] Degrees Fault 4 post-fault phase A current angle
9159 Postfault Ib Mag [3] Amps Fault 4 post-fault phase B current magnitude
9161 Postfault Ib Ang [3] Degrees Fault 4 post-fault phase B current angle
9162 Postfault Ic Mag [3] Amps Fault 4 post-fault phase C current magnitude
9164 Postfault Ic Ang [3] Degrees Fault 4 post-fault phase C current angle
9165 Postfault Va Mag [3] Volts Fault 4 post-fault phase A voltage magnitude
9167 Postfault Va Ang [3] Degrees Fault 4 post-fault phase A voltage angle
9168 Postfault Vb Mag [3] Volts Fault 4 post-fault phase B voltage magnitude
9170 Postfault Vb Ang [3] Degrees Fault 4 post-fault phase B voltage angle
9171 Postfault Vc Mag [3] Volts Fault 4 post-fault phase C voltage magnitude
9173 Postfault Vc Ang [3] Degrees Fault 4 post-fault phase C voltage angle
9174 Fault Type [3] --- Fault 4 type
9175 Fault Location [3] --- Fault 4 location
9176 Prefault Ia Mag [4] Amps Fault 5 pre-fault phase A current magnitude
9178 Prefault Ia Ang [4] Degrees Fault 5 pre-fault phase A current angle
9179 Prefault Ib Mag [4] Amps Fault 5 pre-fault phase B current magnitude
9181 Prefault Ib Ang [4] Degrees Fault 5 pre-fault phase B current angle
9182 Prefault Ic Mag [4] Amps Fault 5 pre-fault phase C current magnitude
9184 Prefault Ic Ang [4] Degrees Fault 5 pre-fault phase C current angle
9185 Prefault Va Mag [4] Volts Fault 5 pre-fault phase A voltage magnitude
9187 Prefault Va Ang [4] Degrees Fault 5 pre-fault phase A voltage angle
9188 Prefault Vb Mag [4] Volts Fault 5 pre-fault phase B voltage magnitude
9190 Prefault Vb Ang [4] Degrees Fault 5 pre-fault phase B voltage angle
9191 Prefault Vc Mag [4] Volts Fault 5 pre-fault phase C voltage magnitude
9193 Prefault Vc Ang [4] Degrees Fault 5 pre-fault phase C voltage angle
9194 Postfault Ia Mag [4] Amps Fault 5 post-fault phase A current magnitude
9196 Postfault Ia Ang [4] Degrees Fault 5 post-fault phase A current angle
9197 Postfault Ib Mag [4] Amps Fault 5 post-fault phase B current magnitude
9199 Postfault Ib Ang [4] Degrees Fault 5 post-fault phase B current angle
9200 Postfault Ic Mag [4] Amps Fault 5 post-fault phase C current magnitude
9202 Postfault Ic Ang [4] Degrees Fault 5 post-fault phase C current angle
9203 Postfault Va Mag [4] Volts Fault 5 post-fault phase A voltage magnitude
9205 Postfault Va Ang [4] Degrees Fault 5 post-fault phase A voltage angle
Table A–1: FLEXANALOG DATA ITEMS (Sheet 12 of 15)