GE Multilin F35 Multiple Feeder Protection System ix
TABLE OF CONTENTS
A. FLEXANALOG
PARAMETERS
A.1 PARAMETER LIST
A.1.1 FLEXANALOG LIST...........................................................................................A-1
B. MODBUS
COMMUNICATIONS
B.1 MODBUS RTU PROTOCOL
B.1.1 INTRODUCTION................................................................................................B-1
B.1.2 PHYSICAL LAYER.............................................................................................B-1
B.1.3 DATA LINK LAYER............................................................................................B-1
B.1.4 CRC-16 ALGORITHM........................................................................................B-2
B.2 MODBUS FUNCTION CODES
B.2.1 SUPPORTED FUNCTION CODES ...................................................................B-3
B.2.2 READ ACTUAL VALUES OR SETTINGS (FUNCTION CODE 03/04H) ...........B-3
B.2.3 EXECUTE OPERATION (FUNCTION CODE 05H) ...........................................B-4
B.2.4 STORE SINGLE SETTING (FUNCTION CODE 06H).......................................B-4
B.2.5 STORE MULTIPLE SETTINGS (FUNCTION CODE 10H) ................................B-5
B.2.6 EXCEPTION RESPONSES...............................................................................B-5
B.3 FILE TRANSFERS
B.3.1 OBTAINING RELAY FILES VIA MODBUS........................................................B-6
B.3.2 MODBUS PASSWORD OPERATION ...............................................................B-7
B.4 MEMORY MAPPING
B.4.1 MODBUS MEMORY MAP .................................................................................B-8
B.4.2 DATA FORMATS.............................................................................................B-55
C. IEC 61850
COMMUNICATIONS
C.1 OVERVIEW
C.1.1 INTRODUCTION................................................................................................C-1
C.1.2 COMMUNICATION PROFILES .........................................................................C-1
C.2 SERVER DATA ORGANIZATION
C.2.1 OVERVIEW........................................................................................................C-2
C.2.2 GGIO1: DIGITAL STATUS VALUES .................................................................C-2
C.2.3 GGIO2: DIGITAL CONTROL VALUES..............................................................C-2
C.2.4 GGIO3: DIGITAL STATUS AND ANALOG VALUES FROM RECEIVED GOOSE
DATAC-2
C.2.5 GGIO4: GENERIC ANALOG MEASURED VALUES.........................................C-2
C.2.6 MMXU: ANALOG MEASURED VALUES...........................................................C-3
C.2.7 PROTECTION AND OTHER LOGICAL NODES...............................................C-3
C.3 SERVER FEATURES AND CONFIGURATION
C.3.1 BUFFERED/UNBUFFERED REPORTING........................................................C-5
C.3.2 FILE TRANSFER ...............................................................................................C-5
C.3.3 TIMESTAMPS AND SCANNING .......................................................................C-5
C.3.4 LOGICAL DEVICE NAME..................................................................................C-5
C.3.5 LOCATION.........................................................................................................C-5
C.3.6 LOGICAL NODE NAME PREFIXES..................................................................C-6
C.3.7 CONNECTION TIMING .....................................................................................C-6
C.3.8 NON-IEC 61850 DATA ......................................................................................C-6
C.3.9 COMMUNICATION SOFTWARE UTILITIES.....................................................C-6
C.4 GENERIC SUBSTATION EVENT SERVICES: GSSE AND GOOSE
C.4.1 OVERVIEW........................................................................................................C-7
C.4.2 GSSE CONFIGURATION..................................................................................C-7
C.4.3 FIXED GOOSE ..................................................................................................C-7
C.4.4 CONFIGURABLE GOOSE.................................................................................C-7
C.4.5 ETHERNET MAC ADDRESS FOR GSSE/GOOSE...........................................C-9
C.4.6 GSSE ID AND GOOSE ID SETTINGS ............................................................C-10
C.5 IEC 61850 IMPLEMENTATION VIA ENERVISTA UR SETUP
C.5.1 OVERVIEW......................................................................................................C-11
C.5.2 CONFIGURING IEC 61850 SETTINGS...........................................................C-12
C.5.3 ABOUT ICD FILES...........................................................................................C-13
C.5.4 CREATING AN ICD FILE WITH ENERVISTA UR SETUP..............................C-17
C.5.5 ABOUT SCD FILES .........................................................................................C-17