DigitalFlow™ GF868 Startup Guide (1 and 2-Channel) 45
Chapter 4. Specifications
4.4 Transducer/Flowcell Specifications
4.4.1 Transducer Type
Standard GE type T5 (welded assembly of Ti transducer). For agency certifications, contact the factory.
4.4.2 Temperature Range
Standard: –94° to +300°F (–70° to 150°C)
Optional high temperature: –94° to +536°F (–70° to +280°C)
Optional low temperature: –364° to +248°F (–220° to +120°C)
4.4.3 Pressure Range
0 to 1500 psig (1 to 1.5 bar)
4.4.4 Materials
Standard: Titanium
Optional: Monel
®
, Hastalloy
®
, and 316 stainless steel
4.4.5 Connections
Cable Length:
Up to 1000 ft (300 m)
Housing Options:
Explosion-proof (Type-7, Class I, Group C & D, Division I.)
Weatherproof (Type-4X, IP65)
Flameproof ( II 2 G EEx d II C T6)
4.4.6 Mounting and Installation
Mechanical insertion mechanism rated to 500°F and 500 psig.