B-32 M60 Motor Protection System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
FlexCurve A (Read/Write Setting)
4910 FlexCurve A (120 items) 0 to 655535 ms 1 F011 0
FlexCurve B (Read/Write Setting)
4988 FlexCurve B (120 items) 0 to 655535 ms 1 F011 0
Modbus User Map (Read/Write Setting)
4A00 Modbus Address Settings for User Map (256 items) 0 to 65535 --- 1 F001 0
User Displays Settings (Read/Write Setting) (16 Modules)
4C00 User-Definable Display 1 Top Line Text --- --- --- F202
4C0A User-Definable Display 1 Bottom Line Text --- --- --- F202 ““
4C14 Modbus Addresses of Display 1 Items (5 items) 0 to 65535 --- 1 F001 0
4C19 Reserved (7 items) --- --- --- F001 0
4C20 ...Repeated for User-Definable Display 2
4C40 ...Repeated for User-Definable Display 3
4C60 ...Repeated for User-Definable Display 4
4C80 ...Repeated for User-Definable Display 5
4CA0 ...Repeated for User-Definable Display 6
4CC0 ...Repeated for User-Definable Display 7
4CE0 ...Repeated for User-Definable Display 8
4D00 ...Repeated for User-Definable Display 9
4D20 ...Repeated for User-Definable Display 10
4D40 ...Repeated for User-Definable Display 11
4D60 ...Repeated for User-Definable Display 12
4D80 ...Repeated for User-Definable Display 13
4DA0 ...Repeated for User-Definable Display 14
4DC0 ...Repeated for User-Definable Display 15
4DE0 ...Repeated for User-Definable Display 16
Field Unit Raw Data Actuals (Read Only) (8 Modules)
4E00 Raw Field Data AC1 Mag 0 to 0.001 A 0.001 F003 0
4E02 Raw Field Data AC1 Angle 0 to 0.1 degree 0.1 F002 0
4E03 Raw Field Data AC2 Mag 0 to 0.001 A 0.001 F003 0
4E05 Raw Field Data AC2 Angle 0 to 0.1 degree 0.1 F002 0
4E06 Raw Field Data AC3 Mag 0 to 0.001 A 0.001 F003 0
4E08 Raw Field Data AC3 Angle 0 to 0.01 degree 0.1 F002 0
4E09 Raw Field Data AC4 Mag 0 to 0.001 A 0.001 F003 0
4E0B Raw Field Data AC4 Angle 0 to 0.01 degree 0.1 F002 0
4E0C Raw Field Data AC5 Mag 0 to 0.001 A/V 0.001 F003 0
4E0E Raw Field Data AC5 Angle 0 to 0.01 degree 0.1 F002 0
4E0F Raw Field Data AC6 Mag 0 to 0.001 A/V 0.001 F003 0
4E11 Raw Field Data AC6 Angle 0 to 0.01 degree 0.1 F002 0
4E12 Raw Field Data AC7 Mag 0 to 0.001 A/V 0.001 F003 0
4E14 Raw Field Data AC7 Angle 0 to 0.01 degree 0.1 F002 0
4E15 Raw Field Data AC8 Mag 0 to 0.001 A/V 0.001 F003 0
4E17 Raw Field Data AC8 Angle 0 to 0.01 degree 0.1 F002 0
4E18 Raw Field Data DC1 0 to 0.001 V 0.001 F002 0
4E19 Raw Field Data DC2 0 to 0.001 V 0.001 F002 0
4E1A Raw Field Data DC3 0 to 0.001 V 0.001 F002 0
4E1B Raw Field Data FCI States (2 items) 0 to 1 --- 1 F500 0
4E1D Raw Field Data SI States 0 to 1 --- 1 F500 0
4E1E Raw Field Data SI Test States 0 to 1 --- 1 F500 0
4E1F Raw Field Data Brick ADC Temperature 0 to 1 degree 1 F002 0
4E20 Raw Field Data Brick Transceiver Temperature 0 to 1 degree 1 F002 0
4E21 Raw Field Data Brick Transceiver Voltage 0 to 0.01 V 0.01 F001 0
4E22 Raw Field Data Brick Transceiver Current 0 to 1 mA 1 F001 0
4E23 Raw Field Data Brick Tx Power 0 to 0.01 dBm 0.1 F002 0