GE Multilin M60 Motor Protection System B-43
APPENDIX B B.4 MEMORY MAPPING
B
7B26 VD Overload Acceleration Intersect at Minimum Volts 1.5 to 20 FLA 0.01 F001 400
7B27 VD Overload Stall Current at 100% Voltage 1.5 to 20 FLA 0.01 F001 600
7B28 VD Overload Safe Stall Time at 100% Voltage 0.1 to 1000 s 0.1 F001 100
7B29 VD Overload Acceleration Intersect at 100% Voltage 1.5 to 20 FLA 0.01 F001 500
7B2A Speed 2 Voltage Dependent Overload Function 0 to 1 --- 1 F102 0 (Disabled)
7B2B Speed 2 VD Overload Minimum Motor Volts 60 to 99 % 1 F001 80
7B2C Speed 2 Voltage Dependent Overload Voltage Loss 0 to 4294967295 --- 1 F300 0
7B2E Speed 2 VD Overload Stall Current at Minimum Volts 1.5 to 20 FLA 0.01 F001 450
7B2F Speed 2 VD Overload Safe Stall Time at Minimum Volts 0.1 to 1000 s 0.1 F001 200
7B30 Speed 2 VD Acceleration Intersect at Minimum Volts 1.5 to 20 FLA 0.01 F001 400
7B31 Speed 2 VD Overload Stall Current at 100% Voltage 1.5 to 20 FLA 0.01 F001 600
7B32 Speed 2 VD Overload Safe Stall Time at 100% Voltage 0.1 to 1000 s 0.1 F001 100
7B33 Speed 2 VD Acceleration Intersect at 100% Voltage 1.5 to 20 FLA 0.01 F001 500
Motor Acceleration Time (Read/Write Grouped Setting)
7B40 Motor Acceleration Function 0 to 1 --- 1 F102 0 (Disabled)
7B41 Motor Acceleration Current 1.00 to 10.00 FLA 0.01 F001 600
7B42 Motor Acceleration Time 0.05 to 180.00 s 0.01 F001 1000
7B43 Motor Acceleration Mode 0 to 1 --- 1 F097 0 (Definite Time)
7B44 Motor Acceleration Block 0 to 4294967295 --- 1 F300 0
7B45 Motor Acceleration Target 0 to 2 --- 1 F109 0 (Self-reset)
7B46 Motor Acceleration Events 0 to 1 --- 1 F102 0 (Disabled)
7B47 Speed 2 Motor Acceleration Current 1.00 to 10.00 x FLA 0.01 F001 600
7B48 Speed 2 Motor Acceleration Time 0.05 to 180.00 s 0.01 F001 1000
7B49 Speed 2 Motor Acceleration Mode 0 to 1 --- 1 F097 0 (Definite Time)
7B4B Speed 2 Motor Acceleration Speed 1-2 0.05 to 180.00 s 0.01 F001 1000
7B4C Speed 2 Motor Acceleration Block 0 to 4294967295 --- 1 F300 0
7B4E Reserved (9 items) --- --- --- F001 0
User Programmable Pushbuttons (Read/Write Setting) (16 Modules)
7B60 User Programmable Pushbutton 1 Function 0 to 2 --- 1 F137 0 (Disabled)
7B61 User Programmable Pushbutton 1 Top Line --- --- --- F202 (none)
7B6B User Programmable Pushbutton 1 On Text --- --- --- F202 (none)
7B75 User Programmable Pushbutton 1 Off Text --- --- --- F202 (none)
7B7F User Programmable Pushbutton 1 Drop-Out Time 0 to 60 s 0.05 F001 0
7B80 User Programmable Pushbutton 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
7B81 User Programmable Pushbutton 1 Events 0 to 1 --- 1 F102 0 (Disabled)
7B82 User Programmable Pushbutton 1 LED Operand 0 to 4294967295 --- 1 F300 0
7B84 User Programmable Pushbutton 1 Autoreset Delay 0 to 600 s 0.05 F001 0
7B85 User Programmable Pushbutton 1 Autoreset Function 0 to 1 --- 1 F102 0 (Disabled)
7B86 User Programmable Pushbutton 1 Local Lock 0 to 4294967295 --- 1 F300 0
7B88 User Programmable Pushbutton 1 Message Priority 0 to 2 --- 1 F220 0 (Disabled)
7B89 User Programmable Pushbutton 1 Remote Lock 0 to 4294967295 --- 1 F300 0
7B8B User Programmable Pushbutton 1 Reset 0 to 4294967295 --- 1 F300 0
7B8D User Programmable Pushbutton 1 Set 0 to 4294967295 --- 1 F300 0
7B8F User Programmable Pushbutton 1 Hold 0 to 10 s 0.1 F001 1
7B90 ...Repeated for User Programmable Pushbutton 2
7BC0 ...Repeated for User Programmable Pushbutton 3
7BF0 ...Repeated for User Programmable Pushbutton 4
7C20 ...Repeated for User Programmable Pushbutton 5
7C50 ...Repeated for User Programmable Pushbutton 6
7C80 ...Repeated for User Programmable Pushbutton 7
7CB0 ...Repeated for User Programmable Pushbutton 8
7DE0 ...Repeated for User Programmable Pushbutton 9
7D10 ...Repeated for User Programmable Pushbutton 10
7D40 ...Repeated for User Programmable Pushbutton 11
Table B–9: MODBUS MEMORY MAP (Sheet 36 of 66)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT