GE Multilin M60 Motor Protection System B-53
APPENDIX B B.4 MEMORY MAPPING
B
A350 ...Repeated for Digital Counter 3
A378 ...Repeated for Digital Counter 4
A3A0 ...Repeated for Digital Counter 5
A3C8 ...Repeated for Digital Counter 6
A3F0 ...Repeated for Digital Counter 7
A418 ...Repeated for Digital Counter 8
Flexcurves C and D (Read/Write Setting)
A600 FlexCurve C (120 items) 0 to 65535 ms 1 F011 0
A680 FlexCurve D (120 items) 0 to 65535 ms 1 F011 0
Non Volatile Latches (Read/Write Setting) (16 Modules)
A700 Non-Volatile Latch 1 Function 0 to 1 --- 1 F102 0 (Disabled)
A701 Non-Volatile Latch 1 Type 0 to 1 --- 1 F519 0 (Reset
Dominant)
A702 Non-Volatile Latch 1 Set 0 to 4294967295 --- 1 F300 0
A704 Non-Volatile Latch 1 Reset 0 to 4294967295 --- 1 F300 0
A706 Non-Volatile Latch 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
A707 Non-Volatile Latch 1 Events 0 to 1 --- 1 F102 0 (Disabled)
A708 Reserved (4 items) --- --- --- F001 0
A70C ...Repeated for Non-Volatile Latch 2
A718 ...Repeated for Non-Volatile Latch 3
A724 ...Repeated for Non-Volatile Latch 4
A730 ...Repeated for Non-Volatile Latch 5
A73C ...Repeated for Non-Volatile Latch 6
A748 ...Repeated for Non-Volatile Latch 7
A754 ...Repeated for Non-Volatile Latch 8
A760 ...Repeated for Non-Volatile Latch 9
A76C ...Repeated for Non-Volatile Latch 10
A778 ...Repeated for Non-Volatile Latch 11
A784 ...Repeated for Non-Volatile Latch 12
A790 ...Repeated for Non-Volatile Latch 13
A79C ...Repeated for Non-Volatile Latch 14
A7A8 ...Repeated for Non-Volatile Latch 15
A7B4 ...Repeated for Non-Volatile Latch 16
IEC 61850 Received Analog Settings (Read/Write) (32 Modules)
AA00 IEC 61850 GOOSE analog 1 default value 1000000 to 1000000 --- 0.001 F060 1000
AA02 IEC 61850 GOOSE analog input 1 mode 0 to 1 --- 1 F491 0 (Default Value)
AA03 IEC 61850 GOOSE analog input 1 units --- --- --- F207 (none)
AA05 IEC 61850 GOOSE analog input 1 per-unit base 0 to 999999999.999 --- 0.001 F060 1
AA07 ...Repeated for IEC 61850 GOOSE analog input 2
AA0E ...Repeated for IEC 61850 GOOSE analog input 3
AA15 ...Repeated for IEC 61850 GOOSE analog input 4
AA1C ...Repeated for IEC 61850 GOOSE analog input 5
AA23 ...Repeated for IEC 61850 GOOSE analog input 6
AA2A ...Repeated for IEC 61850 GOOSE analog input 7
AA31 ...Repeated for IEC 61850 GOOSE analog input 8
AA38 ...Repeated for IEC 61850 GOOSE analog input 9
AA3F ...Repeated for IEC 61850 GOOSE analog input 10
AA46 ...Repeated for IEC 61850 GOOSE analog input 11
AA4D ...Repeated for IEC 61850 GOOSE analog input 12
AA54 ...Repeated for IEC 61850 GOOSE analog input 13
AA5B ...Repeated for IEC 61850 GOOSE analog input 14
AA62 ...Repeated for IEC 61850 GOOSE analog input 15
AA69 ...Repeated for IEC 61850 GOOSE analog input 16
AA70 ...Repeated for IEC 61850 GOOSE analog input 17
Table B–9: MODBUS MEMORY MAP (Sheet 46 of 66)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT

Table of Contents