B-52 M60 Motor Protection System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
VT Fuse Failure Settings (Read/Write) (6 Modules)
A09A VT Fuse Failure Function 0 to 1 --- 1 F102 0 (Disabled)
A09B VT Fuse Failure Neutral Wire Open Function 0 to 1 --- 1 F102 0 (Disabled)
A09C VT Fuse Failure Neutral Wire Open 3rd Harmonic Pickup 0 to 3 pu 0.001 F001 100
A09D ...Repeated for module number 2
A0A0 ...Repeated for module number 3
A0A3 ...Repeated for module number 4
A0A6 ...Repeated for module number 5
A0A9 ...Repeated for module number 6
VT Fuse Failure Actual Values (Read Only) (6 Modules)
A0AC VTFF x V0 3rd harmonic 0 to 999999.999 V 0.001 F060 0
A0AE ...Repeated for module number 2
A0B0 ...Repeated for module number 3
A0B2 ...Repeated for module number 4
A0B4 ...Repeated for module number 5
A0B6 ...Repeated for module number 6
Current Unbalance Actual Values (Read Only)
A200 Current unbalance 0 to 100 % 0.1 F001 0
Selector Switch Actual Values (Read Only)
A210 Selector switch 1 position 1 to 7 --- 1 F001 0
A211 Selector switch 2 position 1 to 7 --- 1 F001 1
Selector Switch Settings (Read/Write) (2 Modules)
A280 Selector 1 Function 0 to 1 --- 1 F102 0 (Disabled)
A281 Selector 1 Range 1 to 7 --- 1 F001 7
A282 Selector 1 Timeout 3 to 60 s 0.1 F001 50
A283 Selector 1 Step Up 0 to 4294967295 --- 1 F300 0
A285 Selector 1 Step Mode 0 to 1 --- 1 F083 0 (Time-out)
A286 Selector 1 Acknowledge 0 to 4294967295 --- 1 F300 0
A288 Selector 1 Bit0 0 to 4294967295 --- 1 F300 0
A28A Selector 1 Bit1 0 to 4294967295 --- 1 F300 0
A28C Selector 1 Bit2 0 to 4294967295 --- 1 F300 0
A28E Selector 1 Bit Mode 0 to 1 --- 1 F083 0 (Time-out)
A28F Selector 1 Bit Acknowledge 0 to 4294967295 --- 1 F300 0
A291 Selector 1 Power Up Mode 0 to 2 --- 1 F084 0 (Restore)
A292 Selector 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
A293 Selector 1 Events 0 to 1 --- 1 F102 0 (Disabled)
A294 Reserved (10 items) --- --- 1 F001 0
A29E ...Repeated for Selector 2
Digital Counter (Read/Write Setting) (8 Modules)
A300 Digital Counter 1 Function 0 to 1 --- 1 F102 0 (Disabled)
A301 Digital Counter 1 Name --- --- --- F205 “Counter 1"
A307 Digital Counter 1 Units --- --- --- F206 (none)
A30A Digital Counter 1 Block 0 to 4294967295 --- 1 F300 0
A30C Digital Counter 1 Up 0 to 4294967295 --- 1 F300 0
A30E Digital Counter 1 Down 0 to 4294967295 --- 1 F300 0
A311 Digital Counter 1 Preset –2147483647 to
2147483647
--- 1 F004 0
A313 Digital Counter 1 Compare –2147483647 to
2147483647
--- 1 F004 0
A315 Digital Counter 1 Reset 0 to 4294967295 --- 1 F300 0
A317 Digital Counter 1 Freeze/Reset 0 to 4294967295 --- 1 F300 0
A319 Digital Counter 1 Freeze/Count 0 to 4294967295 --- 1 F300 0
A31B Digital Counter 1 Set To Preset 0 to 4294967295 --- 1 F300 0
A31D Reserved (11 items) --- --- --- F001 0
A328 ...Repeated for Digital Counter 2
Table B–9: MODBUS MEMORY MAP (Sheet 45 of 66)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT

Table of Contents