18–10 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
MODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL
0160 Port 3: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
0162 Port 3: Number of MAC error packets 0 to
4294967295
1F9 0
0164 Port 3: Number of dropped received
packets
0 to
4294967295
1F9 0
0166 Port 3: Number of multicast frames
sent
0 to
4294967295
1F9 0
0168 Port 3: Number of broadcast frames
sent
0 to
4294967295
1F9 0
016A Port 3: Number of <64 byte fragments
with good CRC
0 to
4294967295
1F9 0
016C Port 4: Number of bytes received 0 to
4294967295
1F9 0
016E Port 4: Number of bytes sent 0 to
4294967295
1F9 0
0170 Port 4: Number of frames received 0 to
4294967295
1F9 0
0172 Port 4: Number of frames sent 0 to
4294967295
1F9 0
0174 Port 4: Total bytes received 0 to
4294967295
1F9 0
0176 Port 4: Total frames received 0 to
4294967295
1F9 0
0178 Port 4: Number of broadcast frames
received
0 to
4294967295
1F9 0
017A Port 4: Number of multicast frames
received
0 to
4294967295
1F9 0
017C Port 4: Number of frames with CRC
error
0 to
4294967295
1F9 0
017E Port 4: Number of oversized frames
received
0 to
4294967295
1F9 0
0180 Port 4: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
0182 Port 4: Number of jabber frames
received
0 to
4294967295
1F9 0
0184 Port 4: Number of collisions occurred 0 to
4294967295
1F9 0
0186 Port 4: Number of late collisions
occurred
0 to
4294967295
1F9 0
0188 Port 4: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
018A Port 4: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1F9 0
018C Port 4: Number of 128 to 255 byte
frames received/sent
0 to
4294967295
1F9 0
018E Port 4: Number of 256 to 511 byte
frames received/sent
0 to
4294967295
1F9 0
0190 Port 4: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1F9 0
0192 Port 4: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
0194 Port 4: Number of MAC error packets 0 to
4294967295
1F9 0
0196 Port 4: Number of dropped received
packets
0 to
4294967295
1F9 0
Table 18–1: Modbus memory map (Sheet 7 of 33)
Address Description Range Step Format Default