CHAPTER 7: ACCESS USING RADIUS ACCESS USING RADIUS
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 7–9
7.3 Configuring 802.1x with EnerVista Secure Web Management software
7.3.1 Commands
To access the 802.1x configuration window, select the Configuration > Radius > Server
menu item.
First, select the server. Do not enable RADIUS capabilities until you have ensured that the
ports are configured properly. After the ports are configured, enable RADIUS. Also ensure
that the port connected to the RADIUS server, or the network where the RADIUS server is
connected to, is not an authenticated port.
The following window shows the configuration of a RADIUS Server. Initially, the RADIUS
Services are disabled and the server IP address is set to 0.0.0.0. Edit the server IP and
secret to add a RADIUS server.