CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOL
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–27
0518 Port 22: Number of MAC error packets 0 to
4294967295
1F9 0
051A Port 22: Number of dropped received
packets
0 to
4294967295
1F9 0
051C Port 22: Number of multicast frames
sent
0 to
4294967295
1F9 0
051E Port 22: Number of broadcast frames
sent
0 to
4294967295
1F9 0
0520 Port 22: Number of <64 byte fragments
with good CRC
0 to
4294967295
1F9 0
0522 Port 23: Number of bytes received 0 to
4294967295
1F9 0
0524 Port 23: Number of bytes sent 0 to
4294967295
1F9 0
0526 Port 23: Number of frames received 0 to
4294967295
1F9 0
0528 Port 23: Number of frames sent 0 to
4294967295
1F9 0
052A Port 23: Total bytes received 0 to
4294967295
1F9 0
052C Port 23: Total frames received 0 to
4294967295
1F9 0
052E Port 23: Number of broadcast frames
received
0 to
4294967295
1F9 0
0530 Port 23: Number of multicast frames
received
0 to
4294967295
1F9 0
0532 Port 23: Number of frames with CRC
error
0 to
4294967295
1F9 0
0534 Port 23: Number of oversized frames
received
0 to
4294967295
1F9 0
0536 Port 23: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
0538 Port 23: Number of jabber frames
received
0 to
4294967295
1F9 0
053A Port 23: Number of collisions occurred 0 to
4294967295
1F9 0
053C Port 23: Number of late collisions
occurred
0 to
4294967295
1F9 0
053E Port 23: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
0540 Port 23: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1F9 0
0542 Port 23: Number of 128 to 255 byte
frames received/sent
0 to
4294967295
1F9 0
0544 Port 23: Number of 256 to 511 byte
frames received/sent
0 to
4294967295
1F9 0
0546 Port 23: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1F9 0
0548 Port 23: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
054A Port 23: Number of MAC error packets 0 to
4294967295
1F9 0
054C Port 23: Number of dropped received
packets
0 to
4294967295
1F9 0
054E Port 23: Number of multicast frames
sent
0 to
4294967295
1F9 0
Table 18–1: Modbus memory map (Sheet 24 of 33)
Address Description Range Step Format Default