NX-10 Expander Installation Guide
145
Location Term Definition
14.4.2 Remote Initiated A menu option that allows an upload/download session
between the module and the PC to be initiated by the PC.
The PC dials into the module. You must dial the data phone
number to dial into the GSM for upload/download.
It is advisable to enable this setting only for a private
network using a firewall.
14.4.3 Auto U/D at Test Time A menu option that configures the module to automatically
dial the PC to initiate an upload/download session after an
autotest. You must program the autotest on the control
panel.
14.4.4 IP Address A menu option that configures the address of the PC
running upload/download software.
14.5 Automation A menu entry that groups automation options.
14.5.1 Enable Automation A menu option that allows automation systems to control
the system via the NX-590E TCP/IP module.
14.5.2 IP Address A menu option that configures the address of the PC
running automation software.
14.6 PremisesConnect A menu entry that groups together the
PremisesConnect.com options.
14.6.1 Enable Premise Server This option enables the premise server application using
the automation port.
14.6.2 Server IP Address This option contains the IP address for the
PremisesConnect.com server.
14.6.3 Automation Port This option contains the automation port for the
PremisesConnect.com server.
14.6.4 Dealer ID This option contains the ID number used to identify the
installer when reporting alarms and events to
Premisesconnect.com.
14.6.5 Reset Encryption Key This option resets the encryption key for the
PremisesConnect.com server.
14.6.6 Register with Premise Server This option allows you to register with the
PremisesConnect.com server.
14.7.1 Reporting A menu entry that groups TCP/IP reporting options.
14.7.1.1 Report Format A menu option that configures the communicator format
used to report to TCP/IP receivers. Consult the instructions
for your central station receiver to determine which format
is compatible.
14.7.1.2 Control Panel is Backup A menu option. This allows the control panel to act as a
backup to the NX-590E. This means that when the NX-590E
fails to send a report, it sends an expansion event to the
control panel and the control panel sends the report
instead.
14.7.1.3 Receiver 2 as Backup A menu option that configures the module to send backup
reports to its second TCP/IP receiver.