Location Term Definition
14.7.1.4 Receiver Polling A menu option that configures the module to send polling
messages to the report receivers.
14.7.1.5 Polling Time A menu option that configures the TCP/IP polling time. This
value must match the TCP/IP polling time set on a TCP/IP
receiver. The value chosen is determined by the level of
security required and the cost of data transmission. This
can be from 1 to 255 seconds. If set to 0, the option is
disabled.
14.7.2 Network A menu entry that groups network options.
14.7.2.1 Use DHCP A menu option that configures the NX-590E to use a
dynamically assigned IP address. If this option is enabled,
you should configure a Polling Time. If this option is
disabled, configure Our E-mail Address, Gateway IP Address
and Subnet Mask.
14.7.2.2 Our IP Address A menu option that configures the IP address assigned to
the module.
14.7.2.3 Gateway IP Address A menu option that configures the IP address of the
gateway used by the module. You must power down the
NX-590E module and power it back up to initialize the new
IP address.
14.7.2.4 Subnet Mask A menu option that configures the subnet mask. This is
typically 255.255.255.0. Contact the network administrator
to confirm. All IP addresses up to and including the local
gateway must be allowed. When using cable modem/DSL,
this mask is the same as that used by the PC.
14.7.2.5 Network Timeout A menu option that configures the maximum overall length
of time by the NX-590E to report to each receiver. If the
report is not successful during this time, the attempt is
abandoned. This can be from 30 to 255 seconds.
14.7.2.6 Max Network Attempts A menu option that configures the number of attempts the
module makes to send a report. This can be from 1 to 15.
14.7.2.7 Port Numbers A menu entry that groups TCP/IP port options.
14.7.2.7.1 TCP/IP Alarm Port A menu option that configures the number of the TCP/IP
port to which polling and alarms are reported. The default
is 9999 and under normal circumstances should not be
changed.
14.7.2.7.2 U/D Port A menu option that configures the number of the port used
for upload/download. The default is 9999 and under
normal circumstances should not be changed.
14.7.2.7.3 E-mail Port A menu option that configures the port number that the
email server uses for email. The default is 0025 and under
normal circumstances should not be changed.
14.7.2.7.4 Automation Port A menu option that configures the number of the port used
for automation. The default is 0000 and under normal
circumstances should not be changed.
14.8 Model A menu option that displays the current model of the
selected module.