– 29 –
To remove the inner door assembly:
Remove the door. See previous page.1.
Place the door assembly, gasket side up, on a 2.
protective surface.
Remove the three 1/4-in. hex-head screws from 3.
the bottom of the door assembly.
Remove the 2 Phillips-head screws from the top 4.
of the inner door assembly.
Note:
The inner door assembly is heavier than the
outer door assembly.
It may be necessary to carefully use a putty
knife in the following step.
Separate the inner door assembly from the 5.
outer door assembly.
To replace the inner door assembly:
Remove the inner door assembly. (See To remove
the inner door assembly.)
Remove the three T-20 Torx screws (3 on each 1.
side) that attach each door hinge to the inner
door. Carefully turn the door over and remove
both door hinges.
Remove the six 1/4-in. hex-head screws that 2.
attach the inner window glass assembly to the
heat barrier.
(Continued next page)
Note: When installing the inner door assembly, rst
capture each top screw using the retainer/spacer.
Retainer/Spacer