Note: On the 11-in. element, the choke must be
removed and transferred to the replacement
element. The choke must be attached at the same
location on the wires and secured with a plastic wire
tie.
Choke
Plastic Wire Tie
Warming Zone Element
The warming zone element operates on •
240 VAC.
The element is rated at 100 watts, has an •
approximate resistance value of 550 Ω, and
draws approximately 0.43 amps.
Warming zone element operation is controlled •
by RPSM duty cycling algorithms. See table
below.
Disconnect
Notch
Tab
Note: The warming zone element is locked into
cutouts in the aluminum plate using 2 tabs. To
remove the element, it is necessary to fi rst position
the tab, located at the 2 o'clock position, into the
release notch.
4. Carefully grasp the outer portion of the element
and rotate it counterclockwise 1 inch until it
reaches the stop position, then lift the element
from the aluminum plate.
To remove the warming zone element:
Remove the aluminum plate. (See 1. Aluminum
Plate.)
Place the aluminum plate element side up on a 2.
protective surface.
Disconnect the wires from the warming zone 3.
element.
Note: The warming zone element is locked into
cutouts in the aluminum plate using 2 tabs. To
remove the element, it is necessary to fi rst position
the tab, located at the 2 o'clock position, into the
release notch.
4. Carefully grasp the outer portion of the element
and rotate it counterclockwise 1 inch until it
reaches the stop position, then lift the element
from the aluminum plate.
SETTING TIME VOLTAGE APPLIED
Hi 79%
Med 54%
Lo 30%