Chapter 1. Introduction
GFK-2224Q January 2017 3
1.3 Ethernet Interfaces for PACSystems Controllers
A PACSystems Ethernet Interface enables a PACSystems controller to communicate with other PACSystems
equipment and with Series 90 and VersaMax controllers. The Ethernet Interface provides TCP/IP
communications with other PLCs, host computers running the Host Communications Toolkit or CIMPLICITY
software, and computers running the TCP/IP version of the programming software. These communications use
the proprietary SRTP and Ethernet Global Data (EGD)
1
protocols over a four-layer TCP/IP (Internet) stack.
The Ethernet Interface has SRTP client/server capability. As a client, the Interface can initiate communications
with other PLCs that contain Ethernet Interfaces. This is done from the PLC ladder program using the COMMREQ
function. As a server, the Ethernet Interface responds to requests from devices such as PLC programming
software, a Host computer running an SRTP application, or another PLC acting as a client.
Figure 1: Ethernet Connection System Diagram
Rack-based and RX7i Embedded Interfaces - Features
Note: The RX3i CPE305/CPE310/CPE330/CPE400 embedded Ethernet interface supports a subset
of these features. For a list of RX3i CPE305/CPE310 embedded Ethernet interface features,
refer to Section 1.3.2. For a list of RX3i CPE330/CPE400 embedded Ethernet interface
features, refer to Section 1.3.3.
Full RX3i Controller programming and configuration services with inactivity timeout
Periodic data exchange using Ethernet Global Data (EGD)
EGD Commands to read and write PLC and EGD exchange memory over the network.
TCP/IP communication services using SRTP
SRTP Client (Channels)
Modbus TCP Server, supporting Modbus Conformance classes 0, 1, and 2.
Modbus TCP Client, supporting Modbus Conformance classes 0, 1, and Function Codes 15, 22, 23, and
24 for Conformance class 2.
Redundant IP Addressing capability.
Basic remote PLC monitoring from a web browser (RX7i CPU Ethernet interface only)
Comprehensive station management and diagnostic tools
Extended controller connectivity via IEEE 802.3 CSMA/CD 10Mbps and 100Mbps Ethernet LAN port
connectors.
1
Effective with RX3i CPE305/CPE310 firmware version 8.30, EGD Class 1 is supported on the embedded Ethernet
Interface. Earlier versions do not support EGD.