8
GEA00362
When Connecting to a 3-Conductor Branch
Circuit:
1. Connect oven red lead to branch circuit red
lead.
2. Connect oven black lead to branch circuit
black lead.
3. Connect oven green ground lead and white
lead to branch circuit neutral (white or gray).
GEA00363
When Connecting to a 4-Conductor Branch
Circuit:
1. Connect oven red lead to branch circuit red
lead.
2. Connect oven black lead to branch circuit
black lead.
3. Break connection between oven white lead
and oven green ground lead.
4. Connect oven white lead to branch circuit
neutral lead (white or gray).
5. Connect oven green ground lead to branch
circuit ground lead (green or bare copper).