To Remove the Left Access Covers:
1. Remove the top access cover (see previous
procedure).
2. Remove 8 screws from the left access cover
and lift off the cover.
To Remove the Rear Access Cover:
1. Remove the top, right, and left access covers
(see previous procedures).
2. Remove 6 screws from the rear access cover.
3. Lift off cover.
To Remove the Lower Front Grille:
1. Remove 3 screws under the grille from the
bottom access panel.
2. Place fingers on each side of the grille.
3. Pull grille forward and upward to disengage
hinge tabs from the chassis.
To Remove the Bottom Access Cover:
1. Remove the lower screws from the right
access panel (5 screws) and rear access
panel (1 screw).
2. Remove the left access panels and lower front
grille (see previous procedures).
3. Remove 7 screws from the bottom access
panel.
4. Lift cover slightly to disengage tabs from oven
chassis.
5. Remove bottom access cover.
Interlocks and Monitor
The primary, door sensing (right and left), and
monitor switches are mounted to plastic latch
boards on the right and left sides of the oven
cavity.
Note: To access the 3 switches in the left latch
assembly, remove 1 screw from the door switch
access cover on the left access panel. Remove
the access cover.
GEA00341
Primary Interlock Test
1. Disconnect the power, remove the enclosure,
and discharge the capacitor.
2. Check the continuity of the switch:
Door closed: 0 ohms
Door open: infinite ohms
Door Sensing Test
Make continuity check between switch terminals.
Normal readings are:
Door closed: 0 ohms
Door open: infinite ohms
Monitor Switch
The bottom latch pawl pushes horizontally and
actuates the lever of the monitor interlock,
opening the switch.
Door closed: infinite ohms
Door open: 0 ohms
Interlock System Test
1. Disconnect the power, remove the enclosure,
and discharge the capacitor.
2. Check the 20-amp fuse for continuity and
proper size. Do not use any other fuse or size
except 20 amp.
3. Remove the monitor switch leads to isolate the
switch.
4. Check continuity of the monitor switch with the
door open and door closed.
Door closed: infinite ohms
Door open: 0 ohms