Performing an Exam
2-56 Versana EssentialUser Guide
5759238-100 English
Rev. 2
Distance measurement
To make a distance measurement:
1. Press Measure.
2. To position the active caliper at the start point, move the
Trackball.
3. To fix the start point, press Set.
The system fixes the first caliper and displays a second
active caliper.
4. To position the second active caliper at the end point, move
the Trackball.
A dotted line connects the measurement points, if preset
accordingly.
5. To complete the measurement, press Set.
The system displays the distance value in the Results
Window.
HINTS
Before you complete a measurement:
To toggle between active calipers, adjust Cursor
Select.
To erase the second caliper and the current data
measured and start the measurement again, press
Clear once.
After
you complete the measurement:
To rotate through and activate previously fixed calipers,
adjust Cursor Select.
To erase all data that has been measured to this point,
but not data entered onto reports, press Clear.