76 ADV200 • Functions description and parameters list
15.35 5474DigAnalogout7ext INT16 16 0 -32768 32767 ERW FVS
Analog output modules can have a resolution of 12 to 16 bits and scaling may vary from manufacturer to manu-
facturer.
E.g.:
12-bit module
Signalconnected
Moduleconfiguration
Variant1 Variant2 Variant3 Variant4
-10V..+10V -2048..+2047 -32768..+32767 -16384..+16383
0V..+10V 0..+4095 0..+2047 0..+16383 0..+32767
4..20mA 0..+32767 +6553..+32767 +3276..+16383
16-bit module
Signalconnected
Moduleconfiguration
Variant1 Variant2 Variant3
-10V..+10V -32768..+32767
0V..+10V 0..+65535 0..+32767
4..20mA
There is no single unit that is suitable for all models of analog output module.
Check the scaling provided by the model being used and use the system variables accordingly.
Analog output 0 and analog output 1 can also be managed by the drive parameters.
To ensure correction operation, the scaling provided by the external module must be compatible with the scal-
ing provided by the drive.
The drive supplies a datum for the I/O modules scaled as follows
Analoginputtype Range
-10V..+10V -32768..+32767
0V..+10V 0..+65535
4..20mA +13107..+65535
Analog outputs 0..1 are managed via drive parameters and the value produced by the drive overwrites that writ-
ten by the MDPLC or serial communication or eldbus.
sysExtIOAnaOut0
sysExtIOAnaOut 1
sysExtIOAnaOut 2
sysExtIOAnaOut 3
sysExtIOAnaOut 4
sysExtIOAnaOut 5
5460 Dig Analog out 0 ext
5462 Dig Analog out 1 ext
5464 Dig Analog out 2 ext
5466 Dig Analog out 3 ext
5468 Dig Analog out 4 ext
5470 Dig Analog out 5 ext
sysExtIOAnaOut 65472 Dig Analog out 6 ext
sysExtIOAnaOut 75474 Dig Analog out 7 ext
R
W
R
W
R
W
R
W
R
W
R
W
R
R
1866 An out 1X mon sysEAO0Value
1868 An out 2X mon sysEAO1Value
P
D
O
P
D
O