42 ADV200 Functions description and parameters list
9–JOGFUNCTION
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
9.1 910 Jogsetpoint rpm INT16 0 CALCI CALCI RW FVS
The reference for Jog mode operation. This reference can also be set via an analog input. The Jog reference
is enabled when the signal used for the Jog+or Jog– command is enabled, the Run command is not present
and the drive output frequency is zero.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
9.2 912 Jogacceleration s FLOAT 5.0 0.01 1000.00 RW FVS
9.3 914 Jogdeceleration s FLOAT 5.0 0.01 1000.00 RW FVS
Setting of the acceleration/deceleration ramp time (in seconds) used during Jog operation.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
9.4 916 Jogcmd+src LINK 16 6000 0 16384 RW FVS
Selection of the origin (source) of the Jog+ function enabling signal. When this command is enabled it gener-
ates a Jog Mode reference with a sign matching the value entered for the Jogsetpointvalue parameter. The
signal to be associated with this function can be selected from the “L_DIGSEL2” selection list.
Note ! The Run command has priority over the Jog+ command.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
9.5 918 Jogcmd-src LINK 16 6000 0 16384 RW FVS
Selection of the origin (source) of the Jog- function enabling signal. When this command is enabled the Jog
Mode reference sign is inverted with respect to the value entered in the Jogsetpointvalue parameter. The
signal to be associated with this function can be selected from the “L_DIGSEL2” selection list.
Note ! The Run command has priority over the Jog-command.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
9.6 920 Jogoutputmon rpm INT16 16/32 0 0 0 ER FVS
The speed reference used by the Jog command is displayed.

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals