AGy-EV Instruction manual Chapter 7 - Parameters Description • 103
d.403 PID integr comp (PID integral component)
PID integral component (%), see figure 7.7.1.
d.404 PID output
PID output signal (%), see figure 7.7.1.
Code LCD display [Code] & LCD select. Default MIN MAX Unit Variation IPA
d.400 PID reference % 0.1 041
d.401 PID feedback % 0.1 042
d.402 PID error % 0.1 043
d.403 PID integr comp % 0.1 044
d.404 PID output % 0.1 045
Alarm list
d.800 1st alarm-latest
Last alarm stored in the drive alarm list (see paragraph 9.3).
d.801 2nd alarm
Second to last alarm stored in the drive alarm list (see paragraph 9.3).
d.802 3rd alarm
Third to last alarm stored in the drive alarm list (see paragraph 9.3).
d.803 4th alarm
Fourth to last alarm stored in the drive alarm list (see paragraph 9.3).
Code LCD display [Code] & LCD select. Default MIN MAX Unit Variation IPA
d.800 1st alarm-latest 046
d.801 2nd alarm 047
d.802 3rd alarm 048
d.803 4th alarm 049
Drive Identification
d.950 Drive rated curr (Drive rated current)
Drive rated current (dependent on the drive size, main voltage and programmed switching frequency): IEC146
Class 1.
d.951 SW version (1/2) (Software version - part 1)
Display example: 03.01
03 = index of software identification
01 = index of software revision (new functions or parameters)
d.952 SW version (2/2) (Software version - part 2)
Display example: 00.00
00 = index of revision (fixing bugs)
00 = index of identification (special version)
NOTE! to be considered as reference for Gefran personell
d.953 Power ident code (Power identification code)
Reserved.