AGy-EV Instruction manual Chapter 7 - Parameters Description • 151
Code LCD display [Code] & LCD select. Default MIN MAX Unit Variation IPA
P.010 Control Mode [0] V/f open loop 0 0 1 498
[1] V/f clsd loop
Power Supply
P.020 Mains voltage
Rated value of the AC input mains line to line voltage [V
rms
].
The undervoltage trip function is based on this value (see also chapter PARAMETERS, function Undervoltage
configuration).
P.021 Mains frequency
Rated value of the AC input mains frequency [Hz].
Code LCD display [Code] & LCD select. Default MIN MAX Unit Variation IPA
P.020 Mains voltage - 230, 380, 400, 420, 440, 460, 480 (****) 230 575 V 404
(Only for "AGy...-4")
- 500, 575 (Only for "AGy...-5")
P.021 Mains frequency 50 (****) 50 60 Hz 405
60
(****) parameter value depending on drive type.
Motor Data
P.040 Motor rated curr (Motor rated current)
Rated current [A
rms
] of the motor at rated kilowatt/horsepower and voltage (given on the nameplate, see figure
7.6.7).
In case of control with multiple motors, enter a value equal to the sum of the rated currents of all the motors.
Do not perform any self tune.
P.041 Motor pole pairs
Pole pairs of the motor.
Starting from nameplate data, the number of pole pairs is calculated as follows:
P=
60 [s] x f [Hz]
n
N
[rpm]
where: p = motor pole pairs
f = rated frequency of the motor (P.062)
n
N
= rated speed of the motor (see figure 7.6.7).
3kW
Motor: 3 phase
1420 rpm
Motor & Co.
Type: ABCDE
400 V
IP54
Made in ..............
6.7 A
IEC 34-1 / VDE 0530
Iso Kl F
Nr
.
12345-91
S1
50 Hz
Power factor
0.8
S.150 (P.040)
S.152 (P.042)
S.101 (P.062)
S.100 (P.061)
I nom
Rated voltage
Rated power
Rated speed (n )
N
2Hp
Motor: 3 phase
1750 rpm
Motor & Co.
Type: ABCDE
575 V
IP54
Made in ..............
2A
IEC 34-1 / VDE 0530
Iso Kl F
Nr
.
12345-91
S1
60 Hz
Power factor
0.83
S.150 (P.040)
S.152 (P.042)
S.101 (P.062)
S.100 (P.061)
I nom
Rated voltage
Rated power
Rated speed (n )
N
Efficiency
86.5
Figure 7.6.7: Motor Nameplate (Example: kW rating for 400V motor and Hp rating for 575V motor)