5.0 - DESCRIPTION OF THE EXTRA FUNCTIONS
,
being the shock sensor regulated at the minimum of the sensibility.
The table below shows the programmable functions.
The manufacturer supplies the alarm with some of these functions disabled (in
order to achieve a good trade-off between ease and completeness of use)
4.10 - SYSTEM DISARMING WITHOUT ALARM MEMORY
4.11 - SYSTEM DISARMING WITH ALARM MEMORY
.
.
.
Pressing the button #1 (dotted) on the remote control or inserting the electronic
key in the receptacle will deactivate the system.
The alarm system will signal this change of status with the led switched off,
three beeps and three flashes of the direction indicators at the same time
If during the armed period attempts have been made to force the vehicle,
during the deactivation stage the alarm will signal the event with two flashes of
the turn signals and, simultaneously, with two low-tone beeps
The last cause of alarm will be signalled with one or more flashes of the turn
signals and a corresponding number of beeps, according to the type of event
5.1 - ACOUSTIC AND OPTIC SIGNALLING
5.2 - REMOTE CONTROLLED PANIC ALARM
FUNCTIONNING
FUNCTIONNING
and optic
P
In the different usage conditions, the alarm signals the current operation or the
alarm memory.
This is done using the turn signals an the LED for the optical signals and using
the siren for the acoustic signals (the last one can be disabled).
During the stages of activation, deactivation, alarm memory, function
programming and learning of new devices, the alarm will produce specific
acoustic signals in order to show which function is being run.
Optic signallings concern either LED or turn signals
The acoustic signals can be high-tone or low-tone.
It allows to generate an alarm condition by pressing button #2 (smooth) on the
remote control.
The panic signals can be as many as desired, but a minimum 5-second interval
must occur between two consecutive signals.
ressing button #2 on the remote control will activate the siren and the
direction indicators for about 30 seconds.
To deactivate the panic alarm, just press again button #2 on the remote control.
This alarm signalling can be activated indifferently of the system status
(activated/deactivated).
Factory setting
Function
Acoustic signals
Panic alarm
Shock sensor
Passive arming
Anti-hijacking procedure
Pre-alarm
Anti-distraction
Status
Enabled
Enabled
Enabled
Disabled
Disabled
Disabled
Disabled
Shock sensor alarm:
Starting attempt
alarm:
Trunk open or lift-up
seat alarm:
Cut wires alarm: