www.generalclimate.com 8 Wall-Mounted Split Type
GC/GU-S09HR
GC/GU-S12HR
GC/GU-S18HR
Ph-V-Hz
1, 220-240V~,50Hz1, 220-240V~,50Hz1, 220-240V~,50Hz
Capacity Btu/h90001200018000
Input W96012301920
Rated current A4,55,79
EER Btu/w.h9,49,89,4
Capacity Btu/h100001300020000
Input W98012901980
Rated current A4,469,2
COP W/W10,29,810,1
A79,110
A2526
36
Model 2P18S225ANKPH225X2C-4FT
SHY33MC2-U
Type RotaryRotary
rotary
Brand GD MatsushitaGD Toshiba
Hitachi
Capacity Btu/h99201361017620
Input W97013051725
Rated current(RLA) A4,56,18,1
Locked rotor Amp(LRA) A242636
Thermal protector External
MRA98745
ExternalInternal
Capacitor uF3035
50
Refrigerant oil mlSUNISO 350430
600
Model
RPG13H
RPG13H
RPG25
Brand WELLINGWellingWELLING
Input W
36,5
36,5
53
Capacitor uF
1.2
μ
F/450V
1,2
1.5uF/450V
Speed(hi/mi/lo) r/min1100/1020/95013501180
m3/h
450/420/390
550/500/460
750/710/650
dB(A)
37/34/31
41/ 38 /34
41/38/35
Model
YDK24-6TYDK24-6YDK25-6H
Brand WELLINGWELLINGWELLING
Input W5572
96
Capacitor uF
2.5
μ
F/450V2.5
μ
F/450V2.5
μ
F/450V
Speed r/min800850
900
m
3
/h
150018002000
dB(A)505254
g650820
1370
MPa
2,6
2,6
2,6
Liquid side/ Gas side mm
Ф
6.35/
Ф
9.53
Ф
6.35/
Ф
12.7
Ф
6.35/
Ф
12.7
Max. refrigerant pipe length m101015
Max. difference in level m558
17-30
17-30
17-30
-7 - 45-7 - 45-7 - 45
m
2
14-2118-2625-35
Operation temp
Ambient temp
Application area
Outdoor noise level
Refrigerant type R410A
Design pressure
Refrigerant
piping
Indoor air flow (Hi/Mi/Lo)
Indoor noise level (Hi/Mi/Lo)
Outdoor
fan motor
Outdoor air flow
Max. current
Starting current
Compressor
Indoor
fan motor
Model
Power supply
Cooling
Heating
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally
somewhat different as a result of ambient condition.
The above design and specifications are subject to change without prior notice for product improvement.