www.generalclimate.com 30 Wall-Mounted Split Type
Ending condition of defrosting
If one of following conditions is satisfied, end the defrost and turn into heating mode:
A. The defrost time has reached to 6 or 10 minutes.
B. The compressor current has reached to I
DEFROST
or above, I
DEROST
differs in different models
Defrosting Actions
Compressor
Outdoor fan
4-way valve
Indoor fan
Defrost 10 or 6 minutes
25s
5s
10s
2s
10.10 Auto mode
10.10.1 The air conditioner automatically selects one of the following operation modes:
cooling, heating or fan only according to the temperature difference between room
temperature (TA) and set temperature (TS).
10.10.2 The indoor fan blows automatically in corresponding selected mode
10.10.3 The motion of indoor fans blade should accord with the selected operation mode
10.10.4 One mode should be carried out for at least 15 minutes once selected. If the
compressor cannot start for 15 minutes, reselect the operation mode according to the room
temp. and set temp., or reselect when the set temp. varies
10.11 Force cooling function
10.11.1 Select forced cooling function with the forced cooling button or the switch
10.11.2 The compressor is unconditionally turned on, after 30 minutes cooling operation
whose fan mode is set as low, the A/C operates at the DRY mode with a set temp. of 24
10.11.3 All protections of remote control cooling are available at forced cooling operation