www.generalclimate.com 34 Wall-Mounted Split Type
12. Troubleshooting
12.1 Display board
§ Operation
The indicator flashes once every second after power is on and illuminates when the air conditioner is in operation.
§ Timer indicator:
The indicator illuminates then TIMER is set ON.
§ PRE-DEF. indicator (For cooling & heating mode only)
The air conditioner starts defrosting automatically if outdoor unit frosts in heating operating.
At this time, PRE-DEF. indicator illuminates.
§ Auto indicator:
This indicator flashes when the air conditioner is in AUTO operation.
§ ECON indicator
This indicator illuminates while the air conditioner is in economic operation.
12.2 Troubleshooting
For cooling mode:
Failure phenomenon
Operation
Timer
Indoor fan speed has been out of control for over 1 minute
Indoor room temp. or evaporator sensor is open circuit or short circuit
Over current protection of the compressor occurs 4 times
r
Extinguish
For heat pump mode:
Failure phenomenon
Operation
Timer
Defrosting
Over current protection of the compressor occurs 4 times
Indoor fan speed has been out of control for over 1 minute
Temp. sensor on indoor evaporator is open circuit or short circuit
Indoor room temp. sensor is open circuit or short circuit
r
Extinguish