turn of all the power to the panel (primary AC sup-
ply, battery backup supply),
set the jumper to the Service position (Fig. 1, item
4) according to the following drawing:
- service position,
connect back the battery, switch on the primary AC
power,
the keypad shall enter service mode,
(optional) use the General > Default codes to re-
store the codes to factory defaults, or „General >
Default settings and codes to restore factory de-
fault settings and codes,
set the jumper to Normal operation position
(Fig. 1, item 4) according to the following draw-
ing:
- normal system operation position.
NOTICE
If the jumper will remain in the service position
and will not be set to the normal opera-
tion position, at an attempt to quit service mode
the panel will return back to service mode.
If the panel will not enter Service mode despite of
the jumper being set to Service position ,