9 SPECIFICATIONS
9.1 PRIMA16 MAIN BOARD
EN50131-1 security grade................................Grade 2
Supply voltage ...............16 – 18V AC ±10%, 50–60 Hz
Standby current consumption (battery)..........100 mA
Max. current consumption (battery)...............300 mA
Standby current consumption (230V).................45mA
Max. current consumption (230V)....................150mA
Power supply type acc. to EN50131-6...............type A
Power supply output voltage..............13,8 V DC ±15%
Battery fault detection voltage..................11,4 V ± 5%
Battery fault restore voltage......................11,9 V ± 5%
Battery cut-off voltage ............................10,5 V ± 10%
Total PSU capacity.....................................................2A
+OUT1, +OUT2 outputs load............................600 mA
PGM3...PGM6 outputs load.............................150 mA
+VX output load................................................600 mA
AUX output load................................................600 mA
Battery charging current...................................500 mA
Environmental class acc. to EN50130-5......................II
Operating temperature range....................-10…+55 °C
Max. humidity........................93±3%, non-condensing
PCB Dimensions...................................150×68×38 mm
Weight.....................................................................99 g