CAUTION
From a safety perspective, class 3R laser products should be treated as poten-
tially hazardous.
Precautions:
1) Prevent direct eye exposure to the beam.
2) Do not direct the beam at other people.
Description Value
Maximum average radiant power <5 mW, Class 3R
Pulse duration Continuous wave
Pulse repetition frequency n.a.
Wavelength 639 nm
Beam divergence 9 mrad (parallel) x
21 mrad (perpendicular)
NOHD (Nominal Ocular Hazard Distance) @ 0.25 s Meets class 3R laser
source specifications