Temperature check set-
tings screens
For each change in temperature of ± 5 °C (± 9 °F) the Zone80
DG returns to the level position to check if the change in temper-
ature has led to a change of the main levelling system.
For a more sensitive unit, you can change the setting to ± 2 °C
(± 4 °F) temperature change.
Available intervals:
Temperature is checked every 5 °C/9 °F
Temperature is checked every 2 °C/4 °F
007627_001
007628_001
Temperature check wait
screens
Relevelling process
When the Zone80 DG is relevelling, the Temperature check wait
screen is displayed. Wait until the process is finished before
using the laser again. The Status LED flashes to indicate normal
levelling.
Temperature sensitivity
settings
36 Zone80 DG Menu