ULTIMA series MAINTENANCE OF THE WASHER
NU_ULTIMA_02_EN_1612 58
2. REGENERATING OF SOFTENER (OPTION)
Only for washers with regeneration (option).
This function is automatic (masked time).
When the display unit indicates "
SALT RECHARGE", it is essential to fill
the salt pot located at the bottom of the chamber, inside the
washer. Use special softening, regenerating salt.
1 Salt pot
2 Filling funnel
3 Salt pot cap
DO NOT FORGET TO REINSTALL SALT POT CAP AFTER FILLING WITH SALT
3. STRAINER FILTERS
Check the cleanness of the strainer filters and clean them if needed.
Debris in the filters will increase the filling times and could activate
the alarm “FILLING FAULT”.
he filters should be replaced each year.
4.
DRYING AIR FILTERS
(Not applicable to 810LX and 815LX)
The life duration of the drying air filters depends on the rate of use
of the washer and the room air quality.
We recommend the preventive change of the drying air filters at
least one time every year.
Check visually the state of the drying air filters every 6 months as
stated in the preventive maintenance scheme