OperationModel: GHM Warmer Series
1. Ensure the Front Curved Glass is lowered to the fully closed position and Sliding Doors are closed.
2. Place Main Power Switch
in the [ON] position.
3. Turn all TOP HEATER control knobs
counter-clockwise to [HI] and set all BOTTOM HEATER controls to the
[10] setting; the Indicator Lights
come on. Allow the unit to preheat approximately 15 minutes.
4. When the Bottom Heater Indicator Lights go out, proceed to the next step (Top Heater Indicators remain ON).
The GHM and its parts become HOT! Temperatures inside the unit may exceed 150°F (65.6°C). Exercise caution
when operating, loading/unloading food, cleaning or servicing. Use of thermal oven mitts or gloves is advised.
Separate Temperature Control Panels are provided for each “pan well zone” ... GHM4 = 3, GHM5 = 4, GHM6 = 5,
GHM8 = 7. Main Power/Light Switch is located on the right-hand panel only.
DO NOT touch the ceramic Top Heaters. They are extremely HOT and skin contact may result in a serious burn.
4.02 Setting & Adjusting Warmer Temperature