6.6. Indoor Power and Communications Interface (Part 1189-PK-021)
The desktop PCI is intended for use in a protected environment and provides interfacing
and power to a single anemometer (Note a separate supply is required for heating).
The PCI is not intended for outdoor use.
Note a mains connector lead only is supplied with the PCI Box.
Connecting to a PCI Unit with RS422 input
Signal
Names
19 Way
Connector
To Connect the PCI RS232 Output (9 Pin D Type connector) to a PC RS232 9 way port to
communicate with the sensor connect as follows:-.
Environmental
PCI Electrical Power Requirements
1) 100Vac – 120Vac, 10VA for the 115V switch position
2) 200 Vac – 250Vac, 10VA for the 230V switch position
3) 20-30Vdc, 120mA max (anemometer)
8-15Vdc, 50mA max (interface)
3 Fuses protect the unit:
1. Externally accessible 315mA (T) for 115/230v operation
2. Internally accessible 500mA (T) AUX
3. Internally accessible 500mA (T) ANEM