How to fix under grid voltage on Ginlong Solis Inverter?
C
Curtis KruegerAug 28, 2025
To address an under grid voltage issue on your Ginlong inverter, use the user-defined function to adjust the protection limit, if allowed by the electrical company.
S
Scott HaneyAug 27, 2025
What to do for over grid voltage on Ginlong Solis Inverter?
C
Christopher AllenAug 27, 2025
If your Ginlong inverter is showing an over grid voltage error:
* The resistance of the AC cable might be too high; try changing to a larger size grid cable.
* If allowed by the electrical company, adjust the protection limit.
D
Daniel JordanAug 26, 2025
How to solve leakage current protection issue on Ginlong Solis Inverter?
X
xwilliamsAug 27, 2025
To resolve a leakage current protection issue on your Ginlong inverter:
1. Check the AC and DC connections.
2. Check the cable connections inside the inverter.
K
Krystal WilliamsAug 25, 2025
How to fix no power on LCD of Ginlong Inverter?
T
Timothy WatersAug 26, 2025
If there is no power on the LCD of your Ginlong inverter, follow these steps:
1. Check the PV input connections.
2. Check the DC input voltage (single phase >120V, three phase >350V).
3. Check if PV+/- is reversed.
M
melissaharveyAug 25, 2025
What to do if there is no grid voltage on Ginlong Solis Inverter?
D
dwalkerAug 25, 2025
If your Ginlong inverter shows no grid voltage, take these steps:
* First, check all connections and the grid switch.
* Then, check the grid voltage inside the inverter terminal.