USER MANUAL
Range BEAT-Tr
Edition: January 2016
- MODE OF USE Revision: No. 3 38
TEMPERATURE RANGE
-20/50ºC
The display shows the current ambient temperature
limits set.
Click the © and ª keys to modify the values and the key ¨ to move to the next field.
Click the START/VALIDATE key to accept the option. Click <STOP> to exit this option
without changing the temperature.
C OPERATOR:
To modify the existing configuration of the option OPERATOR, proceed as follows:
WARNING !
This option might have restricted access. If enabled, the following screen
will appear initially:
OPERATOR: Enter the supervisor PIN number.
Once the supervisor code has been introduced and the START/VALIDATE button pressed,
the following screen that is directly shown that not having the restriction enabled:
>SHOW
COMPULSORY
Pressing START/VALIDATE key the current configura-
tion is showed.
SHOW
<YES>/<NO>
<YES> corresponds to operator’s identification enabled
whereas <NO> to disenabled.
Use the ¨ or § keys to shift from <YES> to <NO> or vice versa. Click the START /
VALIDATE key to accept the selection made. Click <STOP> to exit this option without
making a modification.
The next option allows to establishing the obligation or not in carrying out the identifica-
tion.
SHOW
>COMPULSORY
Pressing START/VALIDATE key the current configura-
tion is showed.
COMPULSORY
<YES>/<NO>
<YES> enables the obligation and automatically makes
that the SHOW option shifts to <YES>.
Use the ¨ or § keys to shift from <YES> to <NO> or vice versa. Click the START /
VALIDATE key to accept the selection made. Click <STOP> to exit this option without
making a modification.
The next option allows to establishing the operator’s identification following ISO 12176-3
criteria in the fields of expiration date and skills (that the operator’s would be allowed to
carry out electrofusion joints).
NOTE !
The fact to enable this option (by selecting <YES>), automatically
disenable the data manual input.