Troubleshooting
102786_en_01 GLW 3-1
English
3 Troubleshooting
3.1 Error messages on the Display
Metering and drive rollers
Table 3-1 Error messages and remedies
Display Cause Remedy
Front door is open. • Close front door.
The error is trig-
gered when the
motor receives cur-
rent but the meter-
ing rollers are not
turning.
The metering roller does not detect a
cable.
• Insert a new cable.
While conveying the cable, it jammed or
made a knot. The drive rollers slip.
• Check if there is a jam or knot.
The force required to unwind the cable
is too large. The drive rollers slip.
• Check if the force required to unwind the cable is too
large.
The rollers do not convey the cable
properly. The drive rollers slip.
• Adjust the clamping pressure of the drive rollers (see
page 3-4).
• Replace the drive rollers (see page 3-4).
• Use drive rollers that suited to the cable (see
page A-1).
The metering roller slips past the cable. • Check if the metering roller is worn.
• Use a metering roller that suits the cable (see
page A-1).
The error is trig-
gered when the
motor current in-
creases too fast.
While conveying the cable, it jammed or
made a knot. The drive rollers are
locked or are about to lock.
• Check if there is a jam or knot.
The force required to unwind the cable
is too large. The drive rollers are locked
or are about to lock.
• Check if the force required to unwind the cable is too
large.
Maximum cutting force exceeded • Check if the cable cross section is too large or if the ca-
ble is for some other reason not suitable.
• Switch the cutter (see page 3-5).
Press the "enter" key to delete the error message.