49
1/A1, AS4777.2./3, RD1699, G83/1, CEI 0-21,
THD(AC output current) <1%
Power factor ~1(Nominal power)
AC Connector Single phase with clamps
Efficiency
Max. efficiency 97.0% 97.0% 97.0%
Euro efficiency >96% >96% >96.5%
MPPT adaptation efficiency >99.5% >99.5% >99.5%
Safety equipment
DC reverse polarity protection Integrated(with diode)
Leakage current monitoring unit Integrated
AC short protection Integrated
DC switch-disconnector Option
Islanding protection AFD
Grid Monitoring
According to VDE-AR-N 4105, VDE0126-1-
1/A1, AS4777.2./3, RD1699, G83/1, CEI 0-21
Normative reference
EMC compliance
According to EN 61000-6-1, EN 61000-6-2,
EN 61000-6-3, EN 61000-6-4
Safety compliance According to IEC62109-1, AS3100
General data
Dimensions (WxHxD) [mm] 330*350*125
Net Weight [kg] 12 13