10 Technical Parameters
49
Technical Data GW12KLV-MT GW15KLV-MT GW20KLV-MT
Cooling Method Smart Fan Cooling
User Interface LED, LCD (Optional), WLAN+APP
Communication RS485, WiFi or 4G or PLC(Optional)
*2
Communication protocols Modbus-RTU(SunSpec Compliant)
Weight (kg) 40.0
Dimensions (W*H*D mm) 480*590*200
Noise Emission (dB) < 60
Topology Non-isolated
Self-consumption at Night (W) < 1
Ingress Protection Rating IP65
Anti-corrosion Class C5
DC Connector MC4( 4~6mm²)
AC Connector OT/DT Terminal (Max. 25mm²)
Environmental Category 4K4H
Pollution Degree III
Overvoltage Category DC II / AC III
Protective Class I
The Decisive Voltage Class (DVC)
PV:C
AC:C
com:A
Active Anti-islanding Method AQDPF
Country of Manufacture China
*1: Subject to the nameplate.
*2: For Brazil Communication is RS485, WiFi, USB, PLC (Optional).