10 Technical Parameters
User Manual V1.3-2023-01-31
52
Technical Data GW25K-MT GW29.9K-MT GW30K-MT GW36K-MT
General Data
Operating Temperature
Range (℃)
-30 ~ 60 (60 °C for outdoor unconditioned with solar eects)
Relative Humidity 0~100%
Max. Operating Altitude (m) 3000
Cooling Method Smart Fan Cooling
User Interface LED, LCD (Optional), WLAN+APP
Communication RS485, WiFi or 4G or PLC(Optional)
*6
Communication protocols Modbus-RTU(SunSpec compliant)
Weight (kg) 40
Dimensions (W*H*D mm) 480*590*200
Noise Emission (dB) < 60
Topology Non-isolated
Self-consumption at Night
(W)
< 1
Ingress Protection Rating IP65
Anti-corrosion Class C5
DC Connector MC4( 4~6mm²)
AC Connector OT/DT Terminal (Max. 25mm²)
Environmental Category 4K4H
Pollution Degree III
Overvoltage Category DC II / AC III
Protective Class I
The Decisive Voltage Class
(DVC)
PV:C
AC:C
com:A
Active Anti-islanding Method AQDPF
Country of Manufacture China
*1: Subject to the nameplate.
*2: 33kW for Italy, 36kW for other country.
*3: For Belgium and Brazil Max. AC Active Power (W): GW25K-MT is 25000; GW30K-MT is 30000.
*4: For Belgium and Brazil Max. AC Apparent Power (VA): GW25K-MT is 25000; GW30K-MT is
30000.
*5: For Brazil Nominal Output Voltage is 380V, 3L/N/PE or 3L/PE.
*6: For Brazil Communication is RS485, WiFi, USB, PLC (Optional)