10 Technical Parameters
User Manual V1.3-2023-01-31
54
Technical Data GW30KLS-MT GW35KLS-MT GW50KS-MT GW60KS-MT
Inrush Current (Peak and
Duration) (A)
50 (at 5ms)
Nominal Output Current (A) 78.7 91.9 72.2 86.6
Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic
Distortion
<3%
Maximum Output
Overcurrent Protection (A)
195
Eciency
Max. Eciency 98.0% 98.0% 98.6% 98.6%
European Eciency 97.7% 97.7% 98.1% 98.1%
Protection
PV String Current Monitoring Integrated
Internal Humidity Monitoring Integrated
PV Insulation Resistance
Detection
Integrated
Residual Current Monitoring Integrated
PV Reverse Polarity Protection Integrated
Anti-islanding Protection Integrated
AC Overcurrent Protection Integrated
AC Short Circuit Protection Integrated
AC Overvoltage Protection Integrated
DC Switch Integrated Integrated
*4
DC Surge Arrester Type II (Type I Optional)
AC Surge Arrester Type II
AFCI Optional
Emergency Power O
*5
/ Optional
Remote Shutdown
*6
Optional
PID Recovery Optional
General Data
Operating Temperature
Range (℃)
-30 ~ +60
Derating temperature (℃) 45