Installation
28 3A6931A
3. Insert the incoming power cord (not included)
through a punch-out on the side of the transformer.
Use a 1 in. (25 mm) cord grip or conduit connection
(not included) where wiring passes through the
punch-out. See Figure 58.
4. Refer to Figure 59 and connect the wires from the
power cord to H1 and H2 inside the transformer.
5. Connect the power cord ground wire to the ground-
ing bar inside the transformer.
NOTE: The wiring to the ram junction box is already
connected to the transformer through the conduit.
6. Replace the transformer cover using the four screws
that were removed in step 2.
FIG. 58: Connect Cord to Transformer
FIG. 59: Ram Transformer Wiring Connections
H3 X3
H2
X2
H1
X1
Connections to Ram Junction Box
Grounding Bar
Connections